Air,
engineered from
first drawing.
We design, supply, install and commission whole-house mechanical ventilation with heat recovery — using precision rigid rectangular ducting from Domus and Greenmill. One accountable team, from analysis to airflow balancing.
Most ventilation fails not at the unit, but in the ducting — in tight bends, leaky joints and routes that were never calculated. We treat the duct network as the engineered backbone of the system, sized and drawn before a single fixing is placed.
A premium ventilation system is a quiet one. Quietness is a by-product of low resistance — and low resistance is designed, never improvised.
That is why every AERIS project begins on the drawing board: room-by-room flow rates, pressure-loss modelling and a fully detailed rigid-duct layout. By the time materials arrive on site, the outcome is already known.
The result is filtered, tempered fresh air in every habitable room, near-silent operation, and documented compliance you can hand to a building inspector with confidence.
Scroll — and the system breathes.
Four stages,
one accountable team.
No hand-offs, no finger-pointing between designer, installer and commissioner. We own the system from the first analysis to the final measured airflow certificate.
Design & Analysis
- Room-by-room extract & supply flow-rate schedule
- Pressure-loss & acoustic modelling of every duct run
- Coordinated CAD drawings & full project documentation
Ductwork Supply & Install
- Genuine Domus & Greenmill rectangular duct & fittings
- Sealed, gasketed joints for measured airtightness
- Acoustic & condensation control on every run
MVHR Installation
- Correctly sized unit for the building's demand
- Insulated condensate & intake/exhaust routing
- F7-grade filtration for clean incoming air
Commissioning & Balancing
- Each terminal balanced to its design flow rate
- Anemometer-measured commissioning certificate
- Homeowner handover, O&M manual & filter schedule
Complete ventilation,
nothing outsourced.
Design intelligence, genuine manufacturer components and certified commissioning — delivered as a single, fixed-scope engagement.
Design, Analysis & Drawings
The first and most important stage. Ventilation calculations, pressure-loss modelling and fully detailed CAD duct layouts that make the build predictable and compliant.
Rigid Rectangular Ductwork
Supply and installation of Domus and Greenmill rigid rectangular duct systems — engineered routes, sealed joints and stable, low-resistance airflow throughout the home.
MVHR Unit Installation
Mechanical ventilation with heat recovery, correctly sized and installed. Up to 90% of outgoing heat reclaimed, with filtered fresh air delivered to every habitable room.
Commissioning & Balancing
Every system is set up, balanced and measured. We tune each terminal to its design flow rate and certify performance — so what was drawn is what you receive.
Delivered &
measured.
Every system handed over with documented, measured airflow. A few representative engagements below.
Illustrative samples — replace with real projects at launchVictorian Terrace Retrofit
Riverside Apartments
Fresh air that
keeps its warmth.
MVHR continuously replaces stale, humid indoor air with filtered fresh air — while a heat exchanger keeps the warmth you have already paid for inside the building.
Up to 90% of the heat in outgoing air is recovered and returned to incoming fresh air.
Pollen, dust and particulates filtered out before air ever enters your living space.
Constant moisture extraction protects the fabric of the building from damp and mould.
Near-silent background ventilation that runs day and night without open windows.
Built on systems
that perform.
We specify rigid rectangular ducting from two of the UK's most trusted manufacturers — chosen for low resistance, durability and a clean, sealed install.
Domus Ventilation's rigid rectangular duct range gives a slim, low-profile run that fits within floor and ceiling voids while maintaining a smooth internal bore — minimising pressure loss and noise across the whole network.
Greenmill AV supplies a comprehensive rigid ducting and fittings system engineered for residential MVHR. Robust, consistent components mean fewer joints, tighter seals and a duct route that behaves exactly as the design predicts.
A clear path,
start to finish.
A typical whole-house project, sequenced so you always know what happens next and who is responsible for it.
Site survey and requirements
We assess the property, discuss the brief and gather the data needed to calculate the system accurately.
Drawings, analysis & fixed quote
Flow-rate schedules, pressure-loss modelling and coordinated duct drawings — delivered with a fixed-scope proposal.
Rigid ductwork installation
Domus and Greenmill rectangular duct routed and sealed to the approved design during the building's first-fix phase.
MVHR unit & terminals
Heat-recovery unit, valves and grilles installed, insulated and connected ready for commissioning.
Commissioning & certification
Every terminal balanced and measured, certificate issued, and the system handed over with full documentation.
Engineers,
not just installers.
Ventilation is an engineering discipline. Every AERIS project is led by accredited specialists across design, installation and commissioning.
Roles shown — named, verifiable team added at launchVentilation Design Engineers
Flow-rate calculations, pressure-loss modelling and fully detailed rigid-duct CAD layouts — the foundation of every system.
Installation Leads
Sealed, gasketed rigid ductwork installed to the approved design — clean routes, airtight joints, condensation control.
Commissioning Engineers
Anemometer-measured balancing of every terminal, with certificates and handover documentation that satisfy building control.
Trusted by
technical buyers.
“The design package was the most thorough we’ve had from a ventilation contractor — our building control inspector signed off without a single query.”
“They gave us proper duct drawings to coordinate against, not a vague schematic. That’s rare, and it saved us on site.”
“Quiet, warm and no condensation anywhere. They handed us measured airflow figures for every room — exactly what was promised.”
Transparent on
what drives cost.
Every system is bespoke, so we scope before we quote. Four factors shape the figure — and we fix the scope before any work begins.
Dwelling size
Number of habitable rooms and wet rooms sets the airflow demand and duct run length.
New build vs retrofit
Retrofits need more design effort to route rigid duct through existing voids and ceilings.
Certification target
Passivhaus or low-energy targets raise the bar on airtightness, modelling and verification.
Duct routing complexity
Constrained routes and acoustic requirements add fittings, labour and design time.
The Part F & ductwork spec one-pager.
A concise reference for architects and developers: required ventilation rates, rigid vs flexible duct, and what a compliant MVHR design must show. Free, no obligation.
Answered
plainly.
If your question isn't here, our engineers are happy to talk it through before you commit to anything.
Start with a
design, not a guess.
Tell us about your project. We'll arrange a survey and return a clear, fixed-scope design proposal — the foundation everything else is built on.
Thank you — request received.
One of our ventilation engineers will be in touch within one working day to arrange your survey.